Surgical Closure Device Painless Surgical Wound Closure Devices
Description
Surgical skin closure is an auxiliary device to help wound healed better, this device is applied on the skin layer after stitched the incision, and this adjustable devioe can make skin closure a fast and easy process.
Capability
1.Holding Power: distance of glide W 2.5mm at 36-38(€
.
.
2.peel strength: average force ^l.ON/an
3.Water vapor transmission: >500g/m2 per 24 hours
4.Pulling force in Parallel direction: after the screw and plastic beam are equipped, the pulling force in the parallel direction is not less than 20N.
5.Aseptic packaging should be intact, no matter, no break or sealed incomplete, no moisture or watermark
6.Peel strength of the seal is between 0.1N/mm-0.5N/mm. The surface are smooth and continuous, without delamincrtion or tearing
7.Sterilized by Ethylene Oxide.
8.After sterilized, 1he Ethylene Oxide residual should less than 10 μg/g.
Specification
Specification |
length |
breadth |
Bl |
ZHQ-63 |
53〜73 |
70-80 |
10-20 |
ZHQ-125 | 115~135 | ||
ZHQ-150 | 140~160 | ||
ZHQ-175 | 165~185 |
Application
Surgical skin dosure is applied to straight surgical incisions or similar straight.
Usage
1.Before use Ihis devioe, please make sure incision had been sutured.
2.Keep your skin dean.
3.Spedficcrtion of surgical skin closure is base on its length. In order to provide auxiliary tension for incision, you can choose suitable specification according to Ihe length of incision, or cut with sterilized scissors to shorten the length of Ihe device. Generally should keep 2cm longerihan Ihe length of incision. For example: if the length of surgical incision is 10cm/ you should choose ZHQ-125.
4.Ihe edge of surgical incision is about 5-10mm from the pbslic beam when using Ihe surgical skin closure.
5.use the adjustable device,adjust the width of the surgical skin closure to the suitable size.So as to adjust the width according to
6.7 steps, and Ihen use Ihe sleeve handle to lighten 1he connecting screw in dockwise Io incision 6.If the incision is edema.the adhesive plaster is tightly connected. the connecting screw can be Counter clockwise rotation by sleeve handle, increase the distance of Iwo surgical skin dosure Io relax to the incision.
7.If Ihe edema subsided,the adhesive plaster is too loosejoss of auxiliary tension,the connecting screw can be dockwise rotation by sleeve handle, narrowing Ihe distance to provide a sense of comfort tension.
8.The device is typically used for7tol4 days, and it is removed by gently peeling from the skin.lfyou still need to maintain a fixed indsioa you can replace a new one.